Duplex Service Drop
1、Application
Primarily used for 120volt overhead service application such as street lighting,outdoor lighting,and temporary service for construction.To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75℃ for polyethylene insulated conductors or 90℃ for crosslinked polyethylene(XLP) insulated conductors.
2、Construction
| Code*Word |
Phase conductor |
Bare Neutral Message |
Nominal lay Length |
Weight Per
1000 ft.(lbs.) |
Allo wable Amp acitles |
Size
(A WG) |
Stranding |
Insul
Thick(Mils) |
Size
(AWG) |
Stranding |
Rated
Strength
(lbs.) |
inches |
XLP |
POLY |
XLP |
POLY |
| AAC Neutral-messenger |
| Pekingese |
6 |
1 |
45 |
6 |
7 |
563 |
10.36 |
61 |
61 |
85 |
70 |
| Collie |
6 |
7 |
45 |
6 |
7 |
563 |
10.36 |
64 |
64 |
85 |
70 |
| Dachshund |
4 |
1 |
45 |
4 |
7 |
881 |
10.36 |
92 |
92 |
115 |
90 |
| Spaniel |
4 |
7 |
45 |
4 |
7 |
881 |
10.36 |
96 |
96 |
115 |
90 |
| Doberman |
2 |
7 |
45 |
2 |
7 |
1350 |
14.88 |
147 |
147 |
150 |
120 |
| Malemute |
1/0 |
9 |
60 |
1/0 |
7 |
1990 |
14.88 |
234 |
234 |
205 |
160 |
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Chihuahua/XLP)
+Conductor temperature of 90℃ for XLP,75℃ for Poly;ambient temperature of 40℃;emissivity 0.2;2ft./sec.Wind in sun.
Triplex Service Drop
1、Application
Used to supply power,usually from a pole-mounted transformer,to the user's service head where connection to the service entrance cable is made.To be used at voltage of 600 volts phase-to-phase or less and at conductor temperature not to exceed 75℃ for polyethylene insulated conductors or 90℃ for crosslinked polyethylene(XLP) insulated conductors.
2、Construction
| Code*Word |
Phase conductor |
Bare Neutral Message |
Nominal lay Length |
Weight Per
1000 ft.(lbs.) |
Allo wable Amp acitles |
Size
(A WG) |
Stranding |
Insul
Thick(Mils) |
Size
(AWG) |
Stranding |
Rated
Strength
(lbs.) |
inches |
XLP |
POLY |
XLP |
POLY |
| AAC Neutral-messenger |
| Pateela |
6 |
7 |
45 |
6 |
7 |
563 |
14.88 |
103 |
103 |
85 |
70 |
| Oyster |
4 |
7 |
45 |
4 |
7 |
881 |
14.88 |
154 |
154 |
115 |
90 |
| Clam |
2 |
7 |
45 |
2 |
7 |
1350 |
20.58 |
233 |
233 |
150 |
120 |
| Murex |
1/0 |
7 |
60 |
1/0 |
7 |
1990 |
20.58 |
374 |
374 |
205 |
160 |
| Purpura |
1/0 |
9 |
60 |
1/0 |
7 |
1990 |
20.58 |
368 |
368 |
205 |
160 |
| Nassa |
2/0 |
7 |
60 |
2/0 |
7 |
2510 |
25.42 |
462 |
462 |
235 |
185 |
| Melita |
3/0 |
17 |
60 |
3/0 |
19 |
3310 |
29.97 |
562 |
562 |
275 |
215 |
| Portunus |
4/0 |
18 |
60 |
4/0 |
19 |
4020 |
29.97 |
696 |
696 |
315 |
245 |
| Nannynose |
336.4 |
19 |
60 |
336.4 |
19 |
6146 |
38.79 |
1118 |
1118 |
420 |
325 |
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Chihuahua/XLP)
+Conductor temperature of 90℃ for XLP,75℃ for Poly;ambient temperature of 40℃;emissivity 0.2;2ft./sec.Wind in sun. |
Quadruplex Service Drop
1、Application
Used to supply 3-phase power,usually from a pole-mounted transformer,to the user's service head where connection to the service entrance cable is made.To be used at voltage of 600 volts phase-to-phase or less and at conductor temperature not to exceed 75℃ for polyethylene insulated conductors or 90℃ for crosslinked polyethylene(XLP) insulated conductors.
2、Construction
| Code*Word |
Phase conductor |
Bare Neutral Message |
Nominal lay Length |
Weight Per
1000 ft.(lbs.) |
Allo wable Amp acitles |
Size
(A WG) |
Stranding |
Insul
Thick(Mils) |
Size
(AWG) |
Stranding |
Rated
Strength
(lbs.) |
inches |
XLP |
POLY |
XLP |
POLY |
| AAC Neutral-messenger |
| Clydessdale |
4 |
1 |
45 |
4 |
7 |
881 |
20.58 |
198 |
198 |
100 |
80 |
| Pinto |
4 |
7 |
45 |
4 |
7 |
881 |
20.58 |
211 |
211 |
100 |
80 |
| Mustang |
2 |
7 |
45 |
2 |
7 |
1350 |
25.42 |
318 |
318 |
135 |
105 |
| Criollo |
1/0 |
9 |
60 |
1/0 |
7 |
1990 |
25.42 |
503 |
503 |
180 |
140 |
| Percheron |
2/0 |
11 |
60 |
2/0 |
7 |
2510 |
29.97 |
619 |
619 |
205 |
160 |
| Hanovarian |
3/0 |
17 |
60 |
3/0 |
19 |
3310 |
35.18 |
764 |
764 |
235 |
185 |
| Oldenburg |
4/0 |
18 |
60 |
4/0 |
19 |
4020 |
35.18 |
945 |
945 |
275 |
210 |
| Lippizaner |
336.4 |
19 |
80 |
336.4 |
19 |
6146 |
38.79 |
1519 |
1519 |
370 |
280 |
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Chihuahua/XLP)
+Conductor temperature of 90℃ for XLP,75℃ for Poly;ambient temperature of 40℃;emissivity 0.2;2ft./sec.Wind in sun |
|